血液分离杯溢口的流体动力设计及影响血液分离的物理参数
A Hydrodynamic Design of the Flooding Port of Cell Separator Blood Processor and the Physical Parameters Affecting the Blood Separation
-
摘要: 本文在“血液锥形分离杯内血液流动稳定性的边界摄动解”[1]的分析基础上,对血液分离杯研制过程中出现的“已分层血液成份重新相混”的现象进行了分析,提出了合理的溢口几何形状,并分析了影响血液分离的各项物理参数. 理论分析得到上海医疗器械研究所实验的证实.Abstract: On the basis of "A Boundary Perturbation Solution for the Hydrodynamic Stability of Blood Flow in a Cone-Type Blood Processor"[1], this paper analyses the phenomenon of that the stratified blood composition Lecomes a mixture again, which occurs in the process of trial-producing with the blood processor, presents a reasonable shape of the flooding port and analyses each physical parameter affecting the blood separation.These theoretical analyses are in agreement with the experimental observations, which have heen made by Shanghai Medical Instruments Institute.
-
[1] 朱月锐、张效慈,血液锥形分离杯内血液流动稳定性的边界簿动解.应用数学和力学.4.4(1983). [2] USP 3409213,3785549. [3] Owner's Operating and Maintenance Manual-Model 3p Cell Separator Blood Processor [4] Tunis,J,L,et al.,Transfusion,7,3(1967),232-242. [5] Tullis,J,L,et al.,Science,124(1956).792-797. [6] 杜马什涅夫,А.Д.,《化学生产机器设备》下册.化工出版社(1958).
计量
- 文章访问数: 1863
- HTML全文浏览量: 160
- PDF下载量: 441
- 被引次数: 0