Wu Wangyi, Dai Guohao. T-Y Tube Model of Human Ascending Aortic Input Impedance[J]. Applied Mathematics and Mechanics, 1997, 18(12): 1049-1058.
Citation: Wu Wangyi, Dai Guohao. T-Y Tube Model of Human Ascending Aortic Input Impedance[J]. Applied Mathematics and Mechanics, 1997, 18(12): 1049-1058.

T-Y Tube Model of Human Ascending Aortic Input Impedance

  • Received Date: 1996-03-20
  • Rev Recd Date: 1997-06-17
  • Publish Date: 1997-12-15
  • This paper proposed a T-Y tube model to simulate foe input impedance of arterial system. It improves and extends the asymmetric T-tube model which was firstproposed by O'Rourke[1] and developed laier by Liu et al.[2]. Based on foe asymmetricT-tube model. a T-Y tube model was proposed by adding branching tubes which represem the iliac arteries.All the tubes are considered to be uniform,viscoelastic longitudinally tethered cylindrical tubes.The upper tube terminates with a windkessel model, while the terminal arterioles of the lowr tube are expressed as a resistance.After proper eraluation of the parameters.the impedance of the arterial system iscalculated under normal physiological and hypertensive condition.The model canpredict impedance in good agreement with the experimentally obtained data no matterin normal physiological condition or in pathological condition In comparison with theasymmeric T-tube model,T-Y tube model is closer to anatomy structure of the human arlerial system and at the sametime much simpler than the extremely complex multiple-branching tube model Therefore it will be a valuable model in studying the influences of various parameters on aorta impedance and ventricular-vascular coupling.
  • loading
  • [1]
    M.F.O'Rourke Pressure and flow waves in systemic arteries and the anatomical designof the arterial system,J.Appl.Phvsiol.23,2 (1967),139-149.
    [2]
    Z.R.Liu,F.Shen and Frank C.P.Yin,Impedance of artrial system simulated byviscoelastic T-tubes terminated in windkessels,Am.J.Physiol,256,25 (1989).H1087-H1099.
    [3]
    W.Gundel,G.Cherry,B.Rajagopalan,L.B.Tan and G.Tee,Aortic input impedanceinman facute response to vasodilator drugs,Circulation,63,6 (1981).1305-1314.
    [4]
    M.F.O'Rourke and A.P.Avolio,Pulsatile now and pressure in human systemicarteries:studies in man and a multi-branched model of the systemic arterial tree,Circ Res 46.3 (1980),363-372.
    [5]
    J.R.Womersley,The mathematical analysis of the systemic arterial circulation in a stateof oscillatory motion,Wright Air Development Center,Technical Report,WADCTR,614 (1957).
    [6]
    M.G.Taylor,The input impedance of an assembly of randomly branching elastic tubes,J.Biophys.6,1 (1966),29-51.
    [7]
    M.F.O'Rourke,Arlerial Fifllctioll in Health and Disease,Edinburgh,Churchill (1982).
    [8]
    W.W.Nichols,C.R.Conti,W.E.Waller and W.R.Milnor,Input impedance of thesystemic circulation in man,Circ.Res. 40.5 (1977).451-458.
    [9]
    U.Gessner.Cardiovascular Fluid Dynamic Vol.l,Ed.by D.H.Bergel,Academic Press,London.New York (1972).